RNA-based drugs - Stevanato Group
Discover how Stevanato Group integrated solutions can help mitigate challenges posed by RNA technology
Home - Managing Complexity, Delivering Value - Stevanato Group > Markets - Stevanato Group > RNA-based drugs - Stevanato Group
page-wrapper

RNA– next-generation technology

The increasing use of RNA-based drugs, both in vials, for a fast time to market and in pre-filled syringes (PFS) for dosing accuracy and ease of use, poses some technical considerations and challenges during the supply chain and cold storage, when applicable, or during life cycle management.

RNA Drug Features

The RNA molecule is typically encapsulated in lipid nanoparticles that exhibit high sensitivity to particulates in the container closure system. This leads to several manufacturing challenges that a drug manufacturer must take into consideration.

Key Challenges
403 Cold Temperature

During the supply chain if in deep-cold storage

164 Product Change Notification

During life cycle management

199A Biologic Molecule

Ensuring drug product stability​

67 Chemical Analysis

Integrating and managing various technology platforms (e.g., lipid nanoparticle formulation)

rna-based cta hero gated DK
rna-based cta hero gated DK

Stevanato Group is the right partner for RNA-based drugs developers since we empower a de-risked strategy with a right-first-time, science based approach.

Stevanato Group can serve RNA-based drugs production processes with comprehensive solutions covering the full pharma value chain.​​
Our unique position in the market enables us to be an integrated provider of primary packaging, machinery, and analytical services.

Stevanato Group is the right partner for RNA technology because we reduce time to market, with a single interface providing a right-the-first-time solution.

infographics integrated offering rna based drug
infographics integrated offering rna based drug

Our Solutions

EZ-fill® Kit

Are you in a clinical phase? Discover how EZ-fill® Kit can help you!

Data and Results

Our EZ-fill® ITC syringes passed all the tests of the main challenges we investigated. Check out the results below:

Glass

Container Closure Integrity (CCI) is maintained at -70°C

Pre-fillable syringes have several components that compose the system, and deep cold storage is a big challenge to maintaining all the materials' integrity.

CCI CHART

Chart: No CO2 was detected in all 30 ITC filled syringes tested through Carbon Dioxide headspace analysis, indicating that no defect allowing CO2 ingress occurred due to any material property changes at -70°C. The controls in both cases performed as expected, showing a substantial ingress of CO2 for the positive control, and no CO2 ingress for the negative controls.

We tested and confirmed no loss of CCI of EZ-fill® ITC syringes after 7 days of storage at -70°C. Tests executed through CO2 Headspace Analysis showed no relevant signals of carbon dioxide ingress after a 1-week freezing cycle whilst also verifying the plunger displacement phenomenon confirming the suitability of EZ-fill® ITC system for mRNA applications.

 

Syringes functionality and closure functionality are not impacted by low temperature of storage.

Low temperature can also affect the functionality of the overall system. Two of the most important parameters that describe the system's functionality are Break Loose and Gliding Force.

Break Loose -40°C

Glide force -40°C

Charts: The test showed that freezing storage has no impact on break loose and gliding force, confirming no functional impact from Room Temperature to -40°C.

We tested - after 1-week storage at -40°C - filled ITC syringes and they showed excellent Break Loose and Gliding Force* performance with comparable results before and after freezing storage.

 

* ISO 11040-4:2015 as a standard reference

ITC unscrewing torque and opening force

We tested the ITC closure unscrew* after 5 cycles at -50° storage with extraordinary results. The test showed no statistical difference in unscrewing torque (Tmax) between the sub-categories, confirming that ITC closure functionality is guaranteed after freezing condition, with no impact on usability for the final user.

Chart: No evidence of difference in unscrewing force for all the 50 ITC syringes tested for each category.

Mechanical properties are not affected after freezing condition storage

Deep cold storage may stress the glass barrel of a PFS system causing potential system failures.

Mechanical resistance

Chart: Results at Room Temperature and at -40°C are comparable, confirming that freezing did not affect glass resistance to breakage.

Regarding mechanical properties, Burst Test* performed on Stevanato Group ITC syringe did not show difference in glass barrel resistance between -40°C and room temperature storage conditions, confirming good mechanical performances.

 

* ISO 7458:2004 as standard reference.

Ensuring CCI at -80°C: Ideal vial solution for pharma cold storage

Market Insight
Covid-19 and the subsequent rise of mRNA vaccines brought new types of therapies to the market that require storage at deep-cold temperatures down to -80 °C.

Risk
The stress on the glass at these low temperatures increases the chance of vial breakage. The risk of breakage is extremely important to pharmaceutical companies due to the high values od drug cointained.

Need
Increased assurance about the compatibility of glass containers with cold storage conditions is key for pharmaceutical companies.

Solution
In this increasingly complex application, EZ-fill® vials are a proven solution to make life easier for customers. Find out Fina® Vial’s optimal performances with deep-cold drug applications and complex cold-chain requirements for both Mechanical & Container Closure Integrity (CCI) performance

Ensuring mechanical resistance with Vertical Compression Test & Burst Test (CTQAs investigated in the study)

Objective
Identify and determine the impact (if any) on glass vials’ mechanical resistance to Axial Load and Internal Pressure of storage conditions of -80°C over a period of 7 days

Method
Vertical Compression and Burst test

Results
2R Fina® quality glass can withstand a conditioning at -80°C for a prolonged period of time without impacting its mechanical performance.

Ensuring Containet Closure Integrity with Headspace Gas Analysis

Objective
Determine CCI during stability at 25°C/60% RH and -80°C at two different time points (T0 and T6 months) over a storage period of 6 months.

Method
Use of Headspace Gas Analysis technique, based on the measurement of the headspace carbon dioxide content in the samples after exposure to a carbon dioxide enriched environment at the target temperatures.

Results
no CO2 detected in all the samples. 2R Fina® vial geometry, in combination with different closure systems, can maintain CCI for a prolonged period of time under the testing conditions

The configurations tested showed no statistically significant difference before and after conditioning.

READ MORE

Mechanical Performances in deep freezing

Mechanical performances scheme

White Paper

mRNA therapies on the rise: Challenges for primary packaging and solutions to test for best performance